Go Back

Licensing failure, cannot access LM server after installing license file

Article Number: 2489
First Published:
Modified:
Recent Activity:
Views: 144
OS: Unix
Product: Licensing

If the error "Licensing failure, Cannot access LM server (not running or MSGWAIT timeout)" occurs after installing the license file or if lmu seems to hang, this could indicate an issue with the set inode values.


If your Synergy License Manager version is 11.1.1c or lower, run lmu -q and chcek to see if there\'s only one license queue. If this shows both queues are exactly the same, like this:


Queues: (ID=32791 KEY=1140983266<0x440205e2>) (ID=32791 KEY=1140983266<0x440205e2>)


then you should upgrade License Manager to a newer version and follow the instructions below.


If your Synergy License Manager version is 11.1.1d or higher, run lmu with no arguments. If lmu warns of an inode problem, running lmu -fixinode should resolve the issue. If it doesn\'t, contact Synergex Support.


Optionally, you can install License Manager version 11.1.1h or higher and try running lmu -altinode to fix the problem,



THE INFORMATION PROVIDED TO YOU IN THIS SERVICE IS FOR YOUR USE ONLY. THE INFORMATION MAY HAVE BEEN DEVELOPED INTERNALLY BY SYNERGEX OR BY EXTERNAL SOURCES. SYNERGEX MAKES NO WARRANTIES, EXPRESS OR IMPLIED, REGARDING THIS INFORMATION, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL SYNERGEX BE LIABLE FOR ANY DAMAGES OR LOSSES INCURRED BY YOU IN USING OR RELYING ON THIS INFORMATION, INCLUDING WITHOUT LIMITATION GENERAL DAMAGES, DIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, OR LOSS OF PROFITS, EVEN IF SYNERGEX HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.